This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
|
docs:blox:connect-switched-outputs [2024/08/05 17:16] admin |
docs:blox:connect-switched-outputs [2024/08/15 12:53] (current) admin |
||
|---|---|---|---|
| Line 1: | Line 1: | ||
| - | ===== 3.9 Switched Output ===== | + | ====== 2.7 Switched Output |
| The Switched Outputs are are used to switch the incoming power supply voltage out to a device. | The Switched Outputs are are used to switch the incoming power supply voltage out to a device. | ||
| Line 9: | Line 9: | ||
| * Suitable for inductive loads | * Suitable for inductive loads | ||
| + | ---- | ||
| - | | Switched Output Example: Motors / LEDs | Switched Output Example: Relays | Switched Output Example: IoT Relay / Solenoid | | + | ===== 2.7.1 Wiring ===== |
| - | | {{: | + | |
| + | | **BLOX Terminal** | **Device** | | ||
| + | | GND | Low side Switched leg | | ||
| + | | V+ | 12-30V (Connected to input power supply positive) | | ||
| + | |||
| + | | **Switched Output Example: Motors / LEDs** | **Switched Output Example: Relays** | **Switched Output Example: IoT Relay / Solenoid** | | ||
| + | | {{: | ||
| + | |||
| + | ---- | ||