This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
|
docs:blox:connect-stepper-motors [2024/08/08 18:31] admin |
docs:blox:connect-stepper-motors [2024/08/15 12:52] (current) admin |
||
|---|---|---|---|
| Line 1: | Line 1: | ||
| - | ===== 2.5 Connecting BLOX to Stepper Motors ===== | + | ====== 2.5 Connecting BLOX to Stepper Motors |
| OpenBuilds BLOX provides support for 2x Bipolar Stepper Motors, with software-controlled current setting and fault monitoring. | OpenBuilds BLOX provides support for 2x Bipolar Stepper Motors, with software-controlled current setting and fault monitoring. | ||
| Line 9: | Line 9: | ||
| ---- | ---- | ||
| - | ==== 2.5.1 Wiring ==== | + | ===== 2.5.1 Wiring |
| > Note: The color codes shown below only apply to OpenBuilds Motors. Refer to [[docs: | > Note: The color codes shown below only apply to OpenBuilds Motors. Refer to [[docs: | ||
| Line 42: | Line 42: | ||
| ---- | ---- | ||
| - | |||
| - | ==== 2.5.3 Configuration ==== | ||
| - | |||
| - | === 2.5.3.1 grblHAL/ | ||
| - | |||
| - | |||
| - | Make sure to set grblHAL settings (CONTROL > Grbl Settings Tab) | ||
| - | |||
| - | * **$140=xx** X-Axis Motor Current (Set appropriate current for stepper motors in use) | ||
| - | * **$141=xx** Y-Axis Motor Current (Set appropriate current for stepper motors in use) | ||
| - | * **$4=0** ;Step direction invert = disabled (Required) | ||
| - | * **$1=255** Step idle delay = set to always enabled (Recommended, | ||
| - | |||
| - | ---- | ||
| - | |||
| - | === 2.5.3.2 LogiBLOX === | ||
| - | |||
| - | You can use the Stepper Motors as linear axes. Current, and all motion parameters like calibration and speed profiles are configurable. Supports relative and absolute movements. | ||
| - | |||
| - | {{: | ||
| - | |||
| - | You can also use the Stepper Motors as Rotational axes. Current, and all motion parameters like calibration and speed profiles are configurable. Supports relative and absolute movements. | ||
| - | |||
| - | {{: | ||
| - | |||
| - | The Stepper Drivers actively monitor for FAULT conditions. | ||
| - | |||
| - | {{: | ||
| - | |||
| - | ---- | ||
| - | |||
| - | |||
| - | |||