docs:blox:connect-stepper-motors

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
docs:blox:connect-stepper-motors [2024/08/08 17:59]
admin
docs:blox:connect-stepper-motors [2024/08/15 12:52] (current)
admin
Line 1: Line 1:
-===== 2.5 Connecting BLOX to Stepper Motors =====+====== 2.5 Connecting BLOX to Stepper Motors ======
  
 OpenBuilds BLOX provides support for 2x Bipolar Stepper Motors, with software-controlled current setting and fault monitoring. OpenBuilds BLOX provides support for 2x Bipolar Stepper Motors, with software-controlled current setting and fault monitoring.
Line 7: Line 7:
   * Motor Inductance: 1-2mH ideally, higher will limit max speed   * Motor Inductance: 1-2mH ideally, higher will limit max speed
  
 +----
  
-==== 2.5.1 Wiring ====+===== 2.5.1 Wiring =====
  
 > Note: The color codes shown below only apply to OpenBuilds Motors. Refer to [[docs:blox:faq-identify-motor-coils|FAQ: Identify Motor coils]] to identify the coil pairs or if you have issues with motors not working correctly.   > Note: The color codes shown below only apply to OpenBuilds Motors. Refer to [[docs:blox:faq-identify-motor-coils|FAQ: Identify Motor coils]] to identify the coil pairs or if you have issues with motors not working correctly.  
Line 22: Line 23:
 | **Wiring NEMA 17 Motors** | **Wiring NEMA 23 Motors** | | **Wiring NEMA 17 Motors** | **Wiring NEMA 23 Motors** |
 | {{:docs:blox:pasted:20240805-145620.png?300}} | {{:docs:blox:pasted:20240805-145547.png?300}} | | {{:docs:blox:pasted:20240805-145620.png?300}} | {{:docs:blox:pasted:20240805-145547.png?300}} |
 +
 +----
  
 ==== 2.5.2 Stepper Driver FAULT modes ==== ==== 2.5.2 Stepper Driver FAULT modes ====
Line 38: Line 41:
   * Note: The FAULT will persist until both cleared, and power has been turned off and on, to protect the stepper drivers   * Note: The FAULT will persist until both cleared, and power has been turned off and on, to protect the stepper drivers
  
- +----
-==== 2.5.3 Configuration ==== +
- +
-=== 2.5.3.1 grblHAL/CONTROL === +
- +
- +
-Make sure to set grblHAL settings (CONTROL > Grbl Settings Tab) +
- +
-  * **$140=xx** X-Axis Motor Current (Set appropriate current for stepper motors in use) +
-  * **$141=xx** Y-Axis Motor Current (Set appropriate current for stepper motors in use) +
-  * **$4=0** ;Step direction invert = disabled (Required) +
-  * **$1=255** Step idle delay = set to always enabled (Recommended, keeps motors locked to maintain position) +
- +
-=== 2.5.3.2 LogiBLOX === +
- +
-You can use the Stepper Motors as linear axes +
- +
-{{:docs:blox:pasted:20240808-175545.png}} +
- +
-You can also use the Stepper Motors as Rotational axes +
- +
-{{:docs:blox:pasted:20240808-175627.png}} +
- +
-The Stepper Drivers actively monitor for FAULT conditions.  FAULT mode for both drivers can be accessed as Digital Sensors +
- +
-{{:docs:blox:pasted:20240808-175754.png}} +
- +
- +
- +
- +
docs/blox/connect-stepper-motors.1723139941.txt.gz · Last modified: 2024/08/08 17:59 by admin