Line 1: | Line 1: | ||
- | ===== 3.7 Connecting BLOX to Stepper Motors ===== | + | ====== 2.5 Connecting BLOX to Stepper Motors |
- | | {{:docs:exclamation.png?40|}} | **IMPORTANT WARNING**: Note: Never connect/ | + | OpenBuilds BLOX provides support for 2x Bipolar Stepper Motors, with software-controlled current setting and fault monitoring. |
+ | |||
+ | * Motor Max Current: 3.2A | ||
+ | | ||
+ | | ||
+ | |||
+ | ---- | ||
+ | |||
+ | ===== 2.5.1 Wiring ===== | ||
> Note: The color codes shown below only apply to OpenBuilds Motors. Refer to [[docs: | > Note: The color codes shown below only apply to OpenBuilds Motors. Refer to [[docs: | ||
- | | Wiring NEMA 17 Motors | Wiring NEMA 23 Motors | | + | | **BLOX Terminal** | **Device** | |
- | | {{: | + | | A+ | Coil 1 (Red) | |
+ | | A- | Coil 1 (Blue) | | ||
+ | | B- | Coil 2 (Green) | | ||
+ | | B+ | Coil 2 (Yellow) | | ||
+ | |||
+ | | {{: | ||
+ | |||
+ | | **Wiring NEMA 17 Motors** | **Wiring NEMA 23 Motors** | | ||
+ | | {{: | ||
+ | |||
+ | ---- | ||
+ | |||
+ | ==== 2.5.2 Stepper Driver FAULT modes ==== | ||
+ | |||
+ | Faults that trigger FAULT MODE: | ||
+ | * Overcurrent (Adjust current down a little) | ||
+ | * Overtemperature (Adjust current down a little, improve cooling) | ||
+ | * Short circuit (Check wiring, Check motor) | ||
+ | * Low Input voltage (Check Power Supply) | ||
+ | |||
+ | If you encounter a Driver Fault: | ||
+ | * Turn off power | ||
+ | * Resolve the issue | ||
+ | * Give the drivers a few minutes to cool down | ||
+ | * Turn power back on | ||
+ | * Note: The FAULT will persist until both cleared, and power has been turned off and on, to protect the stepper drivers | ||
+ | |||
+ | ---- |