-{{:docs:blackbox-x32:blackbox-x32_spin.gif?600|}}+{{:docs:blackbox-x32:blackbox-x32_spin.gif?600}}
  
-{{fa>shopping-cart}}   Order your [[https://openbuildspartstore.com/blackbox-motion-control-system/|OpenBuilds BlackBox X32 Motion Control System]] +{{fa>shopping-cart}} Order your [[https://openbuildspartstore.com/blackbox-motion-control-system/|OpenBuilds BlackBox X32 Motion Control System]]
  
 ---- ----
-===== OpenBuilds® BlackBox Specifications =====+ 
 +===== OpenBuilds® BlackBox X32 Specifications =====
  
   * Plug and Play easy connections that work directly with the OpenBuilds® Xtension wiring ecosystem   * Plug and Play easy connections that work directly with the OpenBuilds® Xtension wiring ecosystem
-  * Muscle & Brains boards stacked configuration +  * 4 x High Powered 4.0A (Peak) Stepper Drivers 
-  * 4 x High Powered 3.2A Stepper Drivers (Max rating 4A+  * Up to 1/32nd Microstepping (Defaulted to 1/8 for higher torque
-  * Auxiliary Serial Input for alternative connectivity expansion+  * Build in Cooling solution / through airflow design 
 +  * Easy current adjustment 
 +  * Capable of full 2/3/4-axes motion control 
 +  * Dual configurable onboard Relays for Plasmas, Spindles, etc 
 +  * Router (Enable) and VFD Spindle (Direction, Enable, 0-10v) Supported 
 +  * PWM Output for Lasers 
 +  * Servo Output for Pen Plotters 
 +  * Up to 24v 5A Switched Output for Coolant or LED devices 
 +  * 3x Optocoupled Endstop Inputs with power supply (5/24v) suitable for passive or active mechanical, optical and inductive switches 
 +  * 1x Optocoupled XYZ Probe Input 
 +  * Door sensor input
   * USB Interface for Plug and Play   * USB Interface for Plug and Play
-  * Power Switch (no more reaching for the power strip or unplugging) +  * WIFI Support 
-  * Easily reachable Current Adjustment Potentiometers +  * SD Card Support 
-  * All new high end Enclosure/Case included, with built in back-lit indication LEDs +  * High performance 32 Bit Processor 
-  * Built in cooling solution/through airflow design +  * Easy V-Slot/C-Beam compatible mounting 
-  * Easy V-Slot compatible Mounting +  * Dimensions: 171mm (Mounting flange includedx 80mm x 36.4mm 
-  * 3 x Endstop inputs with optional power output (Selectable 5v/24vfor use with Mechanical or powered switches such as Inductive sensor +  * Supported by OpenBuilds CONTROL software and all major CAM workflows 
-  * Endstop inputs are protected against high voltages to allow for use of 24v Inductive Sensors +  * Powered by highly customizable and configurable GrblHAL Firmware 
-  * XYZ Probe input + 
-  * Up to 24v 5A switched output for coolant devices such as 24v DC pumps, solenoids, contactors, or Solid State Relays +---- 
-  * Input Power Polarity protection with indicator LED + 
-  * 10 Amp Input Power Fuse +===== FCC Information: ===== 
-  * LED Indicators USB Serial | Power | Polarity | Probe | Motors Enabled | 4x Fault indicators | Coolant, (Spindle/Laser/Toolhead) | RGB LED behind top cover Logo + 
-  * Stepper Driver Fault condition (Overheat, Short Circuitetcindicator LEDs for each axes allows you to pinpoint trouble easier. +This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interferenceand (2this device must accept any interference received, including interference that may cause undesired operation. \\ Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment\\ NOTE: This equipment has been tested and found to comply with the limits for a Class B digital devicepursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. \\ However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, \\ which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 
-  * 5v PWM and 5v Direction Spindle Signals + 
-  * 0-10v Analog Spindle Control Signal Output for VFD Spindles +  * Reorient or relocate the receiving antenna. 
-  * Slave Axis configurable as slave Xor Z +  * Increase the separation between the equipment and receiver. 
-  * Door Interlock signal connector to allow machines with enclosures to pause/resume when the door opens/closes +  * Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 
-  * Up to 1/32 Microstepping (Defaulted to 1/8 for higher Torque) +  * Consult the dealer or an experienced radio/TV technician for help. 
-  * Well planned locations of all connectors to allow for logical cable management + 
-  * Configurable Relay for generic use cases (Plasma trigger, Coolant Pumps, Spindle control, etc+The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction 
 + 