Each operation type described how it works, where to position the probe, and any extra parameters directly onscreen on the Probe Wizard window
-  Clip the magnetic probe to the endmill 
-  Place the Probe Plate on the front-left corner of the stock 
-  Use the buttons onscreen, or your keyboard, to jog the endmill to the position instructed by the wizard 
-  Click [Confirm Probe Position] to confirm the probe hardware is ready. This is a safety step to prevent executing the probing operation without the hardware being ready 
-  Click [Probe] to start the probing operation 